March 10, 2021
Question:
You download sps on PCMCIA card then cut from card read.
Follow the description below carefully to ensure success.
1. Connect TECH2 scan tool to the data link connector.
2. Start TECH2 and select F5: Service Programming System (SPS).
3. Select F0: Request Information.
4. Then select: model year, vehicle type, group, system
5. Follow the instructions in TECH2.
6. Disconnect TECH2 from the vehicle and connect it to the COM port of the computer (flat cable).TIS2000must be installed on the computer.
7. Check that the software of the computer is newer than that of EDC 15/PSG 16. If so, download it to TECH2.
8. Disconnect TECH2 from the computer and reconnect it to the vehicle.
9. Start TECH2 and select F5: Service Programming System (SPS).
10. Select F1: Program control module.
11. Follow the instructions in TECH2.
12. Wait until programming is complete. This takes approx. 7 minutes.
13. Once programming is complete: switch off the ignition.
14. Test start the engine.
15. Read and clear any DTCs in the control unit. A DTC will be generated because the pump control unit loses communication with EDC 15/PSG 16 during programming.
16. Final check:
Clear DTCs in all systems.
Execute one operating cycle (run the vehicle at varying engine load and speed for five minutes).
Evaluate the operating cycle (check that DTCs were not regenerated).
http://blog.obdii365.com/2021/03/09/gm-saab-psg16-pump-sps-programming-via-tech2/
Posted by: jean at
05:52 AM
| No Comments
| Add Comment